Quick Start Video
Quick Start Guide
Good news! ZEN smoke alarm bundle packs arrive to you already interconnected – no need to pair them up as we’ve done it for you. Simply switch your alarms on, perform a test, and you’re good to go!
Switching your alarms ON/OFF
Switch ON: Press down the centre of the alarm (test button) for 5 seconds until the red LED lights up, then release.
Switch OFF: Press down the centre of the alarm (test button) for 5 seconds until the red LED blinks twice, then release.
Testing your alarms
- Press the test button once on the alarm or the remote control. The alarm red LED will flash and will emit an audible tone ‘BEEP BEEP BEEP’.
- If interconnected as a group, all other alarms will do the same.
- Alarms will silence automatically after 10 seconds.
Silencing your alarms
- To silence an alarm after it has been activiated, press the test/silence button on it (or use the remote control).
- If interconnected as a group, all alarms will silence except for the one detecting the issue.
- Press the test/silence button a second time and ALL alarms will become silenced.
- The audible tone stops and the red LED indicator will flash once every 6 seconds indicating the alarm(s) are now in ‘hush mode’.
- Hush mode duration is 10 minutes. After 10 minutes normal smoke alarm operation resumes.
- If smoke particles still remain in the air after 10 minutes, the alarm(s) will sound again.
Setting up a new smoke alarm group with a remote control
- Quick-press the test button twice on ALL the alarms.
- The green LEDs will now flash continuously for 60 seconds, indicating the alarms have all entered the receiving mode. You have a 60 second time window to pair the remote to the alarms.
- Press the ‘pair’ button once on the remote control. The red LED on the remote will illuminate for approx. 10 seconds.
- If pairing is successful the green LED will stop flashing on all the alarms.
- Now press the test button once on the remote to check they are all successfully interconnected.
Setting up a new smoke alarm group without a remote control
- Choose one alarm and quick-press the test button on it 4 times.
- The green LED will now flash continuously for 60 seconds, indicating it has entered transmitting mode. You have a 60 second time window to pair the other alarms to it.
- Quick-press the test button on the other alarms twice. The green LED on the other alarms will flash for a few seconds and then stop, indicating they have been successfully paired.
- After 60 seconds has passed, press the test button once on any alarm to check they are all successfully interconnected.